Ipak ste u pravu, to je to.... u 282 opciju unijeti 147...
Bunilo me zato što sam negdje na nekim centralama vidio da je to "hardware lockout control" ili tako nešto
U svakom slućaju, hvala
A to sam i ja primjetio za Panel ID i PC password, bar na Spectrama... ne znam da li je to slućaj i kod ostalih porodica Paradox alarmnih centrala...
Manje vise:
Kod Esprit-a:
058 ___ / ___ / ___ Installer code lock (147 = locked, 000 = unlocked). When Installer Lock is enabled on a
control panel: For 4 seconds during power up, the BATT LED flashes while the relay
opens and closes making a clicking noise
Hardwerski reset sa jumperom takođe.
Kod Spectri 1759 MG,1728 1738:
[282] ___/___/___ INSTALLER CODE LOCK, DEFAULT: 000 (147 TO LOCK, 000 TO UNLOCK)
Hardwerski reset sa jumperom takođe.
Evo 48 i 192
Blokada reseta:
[3001] __/__/__ (147 = Locked, 000 = Unlocked) INSTALLER LOCK 000
Software Reset:
Performing a software reset will set certain parameters to default values. To do so:
1) Enter Programming Mode (see Entering Programming Mode on page 3).
2) Enter Section [4049] to unlock software reset.
3) Enter the 4-digit [SECTION] corresponding to the software reset you wish to perform.
4) If you want to reset more than one section, enter section [4049] to unlock the software reset again.
Pogledati dalje na 51 stranici koji dio programske liste treba resetirati.
Hardwerski reset:
Panel and Codes Reset
To reset the system back to the factory defaults or custom defaults (if they have been programmed), press and hold the Reset button and the Aux button for
4 seconds (See “PCB Layout” on page 65.)
Na panelu ima tipka RESET koju treba držati pritisnutu 2 sekunde da bi se resetirao panel (bez skidanja napajanja)
MG SP Magellan centrale:
Blokada reseta:
Installer Lock
Section [395]
000 = Disabled, 147 = Lock Enabled, Default = Disabled
Hardwerski reset slično kao i kod evo
Softwerski:[950] Reset all programmable sections to factory default values
DGP 848
Blokada reseta
[990] ___/___/___ (147=lock, 000=unlock) LOCK INSTALLER CODE 000
SOFTWARE RESET
Performing a software reset will set certain parameters to default values. To do so:
1) Make sure the RESET jumper on the control panel is on.
2) Enter Programming Mode (see page 1).
3) Enter the 3-digit [SECTION] corresponding to the software reset you wish to perform:vidi dalje, stranica 40